Lydia ICONOMIDOU-FAYARD
Laboratoire de l'Accélérateur Linéaire, IN2P3 et CNRS,
91405 ORSAY FRANCE
for the NA48 Collaboration [1]
The NA48 detector has been designed [2]
to allow the measurement of in the
neutral kaon system with a total error of 10
. For the detection
of neutral final states a Liquid Krypton calorimeter has been tested and
build offering an excellent energy, position and time resolution. In the
following we present specifications of the detector, results from a small
scale prototype as well as the status of the full scale apparatus.
Also available as